Experiments were undertaken with a small laboratory batch basket centrifuge to determine the dewatering behaviour of final bagasse. With high speeds and extended times, L/F (ration of retained liquid to dry fibre) values below 1.5 (60% moisture) were possible. For reasonable speeds and times typical of a continuous centrifuge, L/F values of about 2.5 (70% moisture) are likely.